Network Connection Settings

The table below lists the ports that are used by default to access Timeline components or for interaction between components. If you are using a software or hardware firewall, make sure that the exception settings for Recording Service have been set up accordingly on the computer where they installed.

If you reassign port numbers, you will need to make changes to the appropriate Windows Firewall rules or to the settings of any other firewall that you are using.

Component name Protocol
type
Port Traffic
direction
Use
Recording Service TCP/IP

80
(if use HTTP)

443
(if use HTTPS)

Inbound HTTP or HTTPS connections to the Recording Service website.
Recording Service TCP/IP

80
(if use HTTP)

443
(if use HTTPS)

Outbound
  • Connections to the PostgreSQL database server.
  • Connections to Timeline.
PostgreSQL TCP/IP 5432 Inbound Connections to the PostgreSQL database server from the remote computer where Recording Service is hosted.